← Browse

CVE-2026-19003

Medium

Elevated severity or exploit probability.

CVSS base
7.8 HIGH
CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
EPSS — probability of exploitation (30 days)
0.2%
5.5th percentile
CISA KEV
Not listed
Weakness / dates
CWE-121
Published 2026-08-12 · modified 2026-09-11

CVSS breakdown

CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H

Attack VectorLLocal
Attack ComplexityLLow
Privileges RequiredNNone
User InteractionRRequired
ScopeUUnchanged
ConfidentialityHHigh
IntegrityHHigh
AvailabilityHHigh

Timeline

Description

A data source definition containing an over-length file path setting may cause the MongoDB BI Connector ODBC Driver setup dialog to write outside the bounds of an allocated buffer. The issue stems from an incorrect buffer capacity calculation in the dialog's file and folder selection handling, and is reached only when a user opens the setup dialog for such a data source and initiates a file or folder selection. Depending on build configuration, the result may range from abnormal process termination to, under certain conditions, execution of unintended code in the context of the user running the dialog.

Affected

mongodb

References

Official: NVD · CVE.org